Strength testing
Test | Slice | Time | Settings | Status | Comment | Image slice | Image samples | Start temp | End temp | Video | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | 3:40:59 | Passes: 24 x 0.25mm Power: 100% Speed: 0.2 - 2.0 mm/s Samples: 4 x 10 Startheight: 68 Offset: -5 | Success | Collection:
The cut quality seems to have diminished at the higher speeds, but no drastically. Top left tripple is last clean trio. Will test heart at 1.4 | -19 -16 | ||||||||
2 | 2 | 3:38:52 | Passes: 32 x 0.25mm Power: 100% Speed: 2.1 - 3.2 mm/s Samples: 7 x 11 Startheight: 68 Offset: -3 | Failed | Slice was very thick, so we had to reduce offset. Mill bit seems to have snapped at 2.1/2.2 mm/s Collection:
| -16 -13 | -19 -15 | |||||||
3 | 3 | 1:32:52 | Passes: 24 x 0.25mm Power: 100% Speed: 1,4 mm/s Samples: 21 Startheight: 68 Offset: -5 | Failed | Spindle didnt start. Will retry the rest | -12 -8 | -14 -10 | |||||||
4 | 3 | 2:32:09 | Passes: 24 x 0.25mm Power: 100% Speed: 1,4 mm/s Samples: 21 Startheight: 68 Offset: -5
| Success | Collection:
I suspect the delay that happends while moving the collector is interferring with the python code recieving plotting data over serial. | -13 -8 | -16 -13 |
Confirmatory testing
Test | Slice | Time | Settings | Status | Comment | Image slice | Image samples | Start temp | End temp | Video | |||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5 | 4 | 47:45 | Passes: 24 x 0.25mm Power: 100% Speed: 1,4 mm/s Samples: 6 Startheight: 68 Offset: -5 | Success | Collection:
Samples hitting sample tube:
| -12 -10 | |||||||||||||||||||||||||||||
5 | 4 | Passes: 24 x 0.25mm Power: 100% Speed: 1,4 mm/s Samples: 6 Startheight: 68 Offset: -5 | Collection:
Samples hitting sample tube:
|