  • Tmax = 2650ºC

  • Inert or reducing atmosphere controlled by multiple MFC's
  • Gas purged into the furnace: Ar (<1800ºC), N2 (1800-2000ºC), He (>2000ºC)

  • A gas analyzer is connected to the furnace and the concentration of CO in the off-gas will be obtained. 

  • Working zone: Ø = 7,5 cm, H = 15 cm

  • Vacuum-chamber: 10-3 mbar (16 m3/h)

  • Sample loading mechanism (elevator)

  • Quenching/cooling chamber (elevator)

  • Gas safety system

  • Online gas analysis system, CO

  • Real time logging and graphs for temperature and analysis
Previously used for:
  • Heating of quarts ranging from 1600 to 2000°Cquartz and silicon carbide in the range of 1700 to 1800ºC  in Ar-CO-H2 gas atmosphere. 

 

 