Typical errorsfix

Restart the machine

tell Håvard etc

 H04 - Laser Fault/error Turn off machine, physically move lens assembly in X and Y axis ( aka. drag it diagonally towards you). Turn machine back on. If error persists, check that there is sufficient cooling water. 
 H34 (also other numbers)  - Pass through Open (abbreviated) The laser has pass through doors on the front and sides (red panels) that slide down to enable larger materials into the machine. Make sure these are closed and locked into place. The front pass through has two metal handles on the inside of the door that locks it into place on both sides. If you want to run with the pass through open, enter the code 1111 followed by the check mark (and run button).
 - Cooling faultCooling unit is turned of. Turn back on and press cross to cancel error message. (or restart machine)
H26Height sensor on the left side of the mirror is stuck. Free Willy (wink)

 

 

Useful resources: 

Box generator: http://boxdesigner.connectionlab.org/

...