Comparison of Low and High Frequency Partial Discharge Measurements on Stator Windings
DOI:
https://doi.org/10.5324/nordis.v0i26.3293Resumen
Partial discharge (PD) testing has been used for over 60 years primarily as a method to assess condition of the stator winding insulation in motors and generators rated 6 kV and above. More recently it has also been used by some machine manufacturers as a means of assuring the quality of the insulation on single winding elements (coils and bars). Although both on-line and off-line tests mainly use a high voltage capacitor to detect the PD, the PD measuring systems in use work either in the low frequency (LF) regime (less than about 1 MHz) or in the very high frequency (VHF) (30-300 MHz) range. By reference to several international standards, published work as well as some experiments described in this contribution, the advantages and disadvantages of the two approaches are compared. Based on this work, it is now clear that off-line PD tests should be done in the LF range. For on-line tests, either method may be used, but use of the VHF method has become more widespread with machine end users, since the owners themselves can perform and interpret the results with a relatively low risk of false indications.
Descargas
Descargas
Publicado
Número
Sección
Licencia
Proceedings of the Nordic Insulation Symposium licenses all content of the journal under a Creative Commons Attribution (CC-BY) licence. This means, among other things, that anyone is free to copy and distribute the content, as long as they give proper credit to the author(s) and the journal. For further information, see Creative Commons website for human readable or lawyer readable versions.
Authors who publish with this journal agree to the following terms:
1. Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
2. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
3. Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).