Use of Data-Driven Approaches for Defect Classification in Stator Winding Insulation

Forfattere

  • Emre Kantar SINTEF Energy Research
  • Jaume M. Cascallo NTNU
  • Torstein G. Aakre SINTEF Energy Research
  • Nina M. Thomsen SINTEF Energy Research
  • Espen Eberg SINTEF Energy Research

DOI:

https://doi.org/10.5324/nordis.v27i1.4579

Resumé

Partial discharges (PD) in the high voltage insulation systems are both a symptom and cause of terminal and impending failures. The use of data-driven methods based on PD measurements will enable predictive strategies to replace traditional maintenance strategies. This paper employs machine learningbased classification models to identify and characterize
PD signals originating from lab-made artificial defects in epoxy-mica material samples. Three different PD sources were studied: surface discharges in air, corona discharges, and discharges caused by internal cavities/delaminations. To generate high-quality datasets for the training, validation, and testing of classification models, Phase-Resolved PD (PRPD) data for each test object was obtained at room temperature under 50 Hz AC excitation at 10 % above the PD inception voltage (PDIV) of each sample. Relevant statistical and deterministic features were extracted for each observation and were labeled based on the defect type (supervised learning). Finally, the trained and validated ML models were used to identify PD sources in the service-aged stator winding insulation. Support vector machines (SVM), ensemble, and k-nearest neighbor (kNN) algorithms achieved significantly high accuracy (≥ 95 %) of defect identification.

Downloads

Download-data er endnu ikke tilgængelig.

Downloads

Publiceret

2022-07-05